Converting to Fuel
Circulation of Biomass Energy: to create a resource-recycled society
There are limited resources in fossil fuels (oil, coal, etc), but there are also recyclable natural resources that can be converted into energy: Biomass.
Biomass is the general organic resources such as sawmill residue, thinning woods, forest residues (leaves and branches), sawdust from construction, livestock waste, municipal waste from restaurants, convenience stores, and house kitchens. This biomass has been treated and managed as waste, but to convert this biomass to energy and to use this biomass energy (bioenergy) can progress the world.
Motoyama Shoji, Inc strives to create and contribute to a resource-recycling society, and our new developed machinery will certainly help to create earth friendly environment.
Our machinery, Recycled Energy and Electricity from Sawmill
Residue, was approved by the governor of Chiba prefecture
for a renovated innovation planning based on gOrganization
for Small & Medium Enterprises and Regional Innovation.h
The followings are the test results of energy produced by
our machinery.
| Example
of Coal and Petroleum Coke Analysis |
| Charcoal
Category |
Lignite |
Lignite |
Lignite |
Sub-bituminous
Coal |
Bituminous
Coal |
Bituminous
Coal |
Bituminous
Coal |
Bituminous
Coal |
Anthracite |
Petroleum
Coke |
| Coutry
Location |
Australia
Yarun |
USA
Rochelle |
Indonesia
Pasir |
Japan
Pacific Ocean |
Australia
Ehnbenezer |
China
Datong |
Australia
Ensham |
Australia
Newlands |
Vietnam
Hon Gai |
USA
Chevron |
Total
Moisture (wt%) |
34.3 |
25.2 |
18.5 |
12 |
10 |
8 |
8 |
8 |
8 |
8.1 |
Heat
Value (kcal/kg) |
4,100 |
5,860 |
6,200 |
6,200 |
6,700 |
6,810 |
7,000 |
6,820 |
8,050 |
8.,670 |
HGI |
|
49 |
448 |
42 |
40 |
50 |
57 |
58 |
31 |
75 |
*Analysis is based on the followings. Total Moisture: Based on arrival; Heat
Value: Based on air-dried basis
| Measurement
Test Result of Energy Generated by Our Machinery
|
Test Item |
Unit |
Test
Result |
Test
Method |
Gross Heat Value |
Kcal/kg |
7780 |
JSK 2279 |
Gross Heat Value |
MJ/kg |
32.4 |
JSK 2279 (Unit
Conversion) |
Total Moisture |
% |
1.39 |
Loss on Drying |
Moisture |
% |
1.39 |
Loss on Drying |
Ash Content |
% |
18 |
Loss on Drying |
Volatile Portions |
% |
0 |
Motoyama-Shoji
Own Method |
Fixed Carbon |
% |
81 |
Calculation |
Kjeldahl Nitrogen |
% |
0.32 |
Kjeldahl Method |
Chlorine |
% |
Less than 1 |
Titration Method |
Dec. 28, 2001
MRC UNITEC CO.,LTD.
1Ban 109Go 3Chome Kouyou Hachido-Shi Aomori-Ken 031-0801
Flue Gas Measurements
Location - Motoyama Shoji, Inc. Hachinohe Factory
Measured company - MRC UNITEC CO.,LTD. (Dioxin is measured by MIURA CO., LTD.)
|
Energy Main Ingredient |
|
Average |
Measurement Data |
Outcome |
| Kerosene
& Chicken Manure |
Measurement of Soot and Dust
Concentration |
0.30 |
0.041 |
Passed |
| |
Measurement of Sulfuric Oxide |
0.60 |
0.00 |
Passed |
| |
Measurement of Nitrogen Oxides |
350 |
113 |
Passed |
| |
Measurement of Sulfuric Oxide |
641.52 |
207.12 |
Passed |
| |
Measurement of Nitrogen Oxides |
816 |
264 |
Passed |
| Kerosene
& Chicken Manure |
Measurement of Soot and Dust
Concentration |
991.22 |
320.07783 |
Passed |
| |
Measurement of Nitrogen Oxides |
1341 |
433 |
Passed |
| Kerosene
& Chicken Manure |
Measurement of Soot and Dust
Concentration |
1515.77 |
489.51633 |
Passed |
| |
Measurement of Sulfuric Oxide |
1690.62 |
546.00 |
Passed |
|